I had problem to power up the machine when powered off during night.
Had to leave power on for 15-30min then power off and power on again to get it started.
Otherwise I got an alarm on spindle controler, and if I looked at spindle controler it was completely dead.
Problem was solved by changing all the capacitor in the power supply of spindle controler.
capacitors it one of the parts of electronic that is ageing and need to be replaced on old equipment.
Ps. This is just a tips if someone has a simular problem...
Had to leave power on for 15-30min then power off and power on again to get it started.
Otherwise I got an alarm on spindle controler, and if I looked at spindle controler it was completely dead.
Problem was solved by changing all the capacitor in the power supply of spindle controler.
capacitors it one of the parts of electronic that is ageing and need to be replaced on old equipment.