Hello,
Does anyone know the proper procedure for restarting an EIA program on a T32-2 control (Super QuickTurn 15MS)?
I have tried placing line numbers (e.g. N100) in the program and using the following key sequence:
Position > Restart > N SEQ-No. > 100 > Input > EIA/ISO Search
But I receive the message 425 Data Missing
Any advice?
UPDATE
Our manuals turned up. Here is the proper procedure to restart an EIA program on a T32 control:
Position > Restart > N SEQ-No. > 100 > Input > B BLCK-No. > 0 > L > 1 > EIA/ISO Search
The BNo. Parameter is equivalent to a line number. The L parameter is the number of occurrences that should be skipped minus one. If there is more than one match for the N SEQ-No. that you searched for then it will restart the program at the match number which is equivalent to L.
Example:
N B L
100 0 3
N100 (skip)
G0
N100 (skip)
G0
N100 (match - program starts here)
G0
Does anyone know the proper procedure for restarting an EIA program on a T32-2 control (Super QuickTurn 15MS)?
I have tried placing line numbers (e.g. N100) in the program and using the following key sequence:
Position > Restart > N SEQ-No. > 100 > Input > EIA/ISO Search
But I receive the message 425 Data Missing
Any advice?
UPDATE
Our manuals turned up. Here is the proper procedure to restart an EIA program on a T32 control:
Position > Restart > N SEQ-No. > 100 > Input > B BLCK-No. > 0 > L > 1 > EIA/ISO Search
The BNo. Parameter is equivalent to a line number. The L parameter is the number of occurrences that should be skipped minus one. If there is more than one match for the N SEQ-No. that you searched for then it will restart the program at the match number which is equivalent to L.
Example:
N B L
100 0 3
N100 (skip)
G0
N100 (skip)
G0
N100 (match - program starts here)
G0