Mazak T32-2 EIA Program Restart

$
0
0
Hello,

Does anyone know the proper procedure for restarting an EIA program on a T32-2 control (Super QuickTurn 15MS)?

I have tried placing line numbers (e.g. N100) in the program and using the following key sequence:

Position > Restart > N SEQ-No. > 100 > Input > EIA/ISO Search

But I receive the message 425 Data Missing

Any advice?

UPDATE

Our manuals turned up. Here is the proper procedure to restart an EIA program on a T32 control:

Position > Restart > N SEQ-No. > 100 > Input > B BLCK-No. > 0 > L > 1 > EIA/ISO Search

The BNo. Parameter is equivalent to a line number. The L parameter is the number of occurrences that should be skipped minus one. If there is more than one match for the N SEQ-No. that you searched for then it will restart the program at the match number which is equivalent to L.

Example:

N B L
100 0 3

N100 (skip)
G0
N100 (skip)
G0
N100 (match - program starts here)
G0