Quantcast
Channel: Practical Machinist - Largest Manufacturing Technology Forum on the Web - Mazak
Viewing all articles
Browse latest Browse all 2364

M32 887 Tape I/O error

$
0
0
Hi all,

I scoured this forum for 877 errors on M32 controls but could not really get good posts.

I have the same problem on two different machines:

AJV-18 Vertical Mill
H400 Horizontal Mill

Both M32 controls.

We drip feed for about 40 min. and then an 887 Tape I/O ((Check parameters for incorrect settings) error appears.

I checked all G parameters that have to do anything with getting data in and out.
G1
G10

G19
G20
G21
G22
G23

G55
G56
G57
G58
G59

I am using the http://www.highlanddnc.com/ ShopLink FLASH 2.0, "DNC in a box" as my sending unit.

Stop bits are set to 7 on the sending config file and 8 in the M32 control.

I checked all other G parameters and they matched my parameter sheets.

Are there any other parameters that I need to attend to that effect Drip Feeding?


I just talked to Jerry from Highland DNC and he suggested to take out all comments in the part file.
We are test running it again now.


Thanks for any help.

Rider7